The Series 9239, Compensated Density logging tool uses
the two focused density detectors to compute borehole
compensated density real time while logging. No post
processing required to produce CDL bulk density.
Additionally, the tool also records natural gamma, caliper ,
and focused guard resistivity
FEATURES
Properties Measured
1.   Natural Gamma:
2.2 x 10.16 cm (0.875 x4.0 in.)
NAI Scintillation
Offset: 21 cm (8.25 in.)
2.   3-Element Guard Resistivity:
127.6 mm (50.25 in.) guard electrode
Offset: 63.5 cm (25 in.)
3.   Caliper:
Motorized, uphole actuated
35.6 cm (14 in.) or 20.3 cm (8 in.)
Offset: 210.8 cm (83 in.) 
4.  Far Density:
2.2 x 10.16 cm (0.875 x4.0 in.)
35.8 cm (14.1 in.) spacing
Offset: 243.3 cm (95.8 in.)
5,  Near Density:
2.2 x 3.2 cm (0.875 x1.25 in.)
20 cm (7.9 in.) spacing
Offset: 259.3 cm (102.1 in.)
6.   Radioactive source:
200-300 mCi Cesium 137 in bullplug
Offset: 274.3 cm (108.0 in.)
Length:280.3 cm (110.35 in.)
Temperature: 85 C (185 F)
Diameter: 56 mm (2.2 in.)
Pressure: 175 kg/cm2 (2500 PSI)
Weight: 32.7 kg (72 lb.)
Logging Speed: 9 m/min. (30 ft./min.)
Tool Voltage Required: 56 VDC
TOOL#: 9239